{"title":"Hardware for the Complete PACLearn Series","description":"\u003cspan\u003eNot all of these products are necessary to complete the projects in the lab project manual, this allows you to see all of the appropriate products that could be used in that endeavor.\u003c\/span\u003e","products":[{"product_id":"universal-digital-field-device-simulator-use-with-plc2-3-5-slc500-micrologix1000-1100-1200-1400-1500-controllogix-or-compactlogix","title":"28 - Universal Digital Field Device Simulator -         Use with PLC2\/3\/5, SLC500 - Micrologix1000, 1100, 1200, 1400, 1500 - ControlLogix or CompactLogix or any PLC with DC I\/O","description":"\u003cp\u003e\u003cstrong\u003ePlease allow 7 to 15 business days for shipment of this product.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003eThe simulators ship with 24\" fly-outs (wires to connect to your controller). \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eA universal I\/O simulator with six multipurpose input simulators and six highly visible output simulators:\u003c\/p\u003e\n\u003cp\u003eThis field device simulator can be integrated with any controller, any size and any brand.\u003c\/p\u003e\n\u003cp\u003e1. Six multipurpose input field device simulators:\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003eMulti-state simulator; using a selector switch or a pushbutton alone can be awkward to operate when exercising your logic in the controller.\u003c\/p\u003e\n\u003cp style=\"padding-left: 60px;\"\u003eThe electrical interface (field wiring) to the six input field device simulation is one common conductor to all six pairs of switches and one dedicated conductor per pair for landing on the I\/O modules terminal block. They are not polarity sensitive, they are all dry contacts.\u003c\/p\u003e\n\u003cp style=\"padding-left: 60px;\"\u003e\u003cstrong\u003eMaintained ON\u003c\/strong\u003e or \u003cstrong\u003eMaintained Off\u003c\/strong\u003e - There are instances that you would like to change the state of a simulated input field device and leave it in that state indefinitely.\u003c\/p\u003e\n\u003cp style=\"padding-left: 60px;\"\u003e\u003cstrong\u003eNormally Open\u003c\/strong\u003e or \u003cstrong\u003eNormally Closed\u003c\/strong\u003e - There are other situations where a single hand motion to change the state momentarily reduces distraction from concentrating on the code and not the simulation of field devices. This is where a pushbutton is the best solution.\u003c\/p\u003e\n\u003cp style=\"padding-left: 90px;\"\u003eIn most cases... A normally open pushbutton will suffice for the quick momentary change of state and for that reason all six of our input field device simulators have an adjacent pushbutton that functions as normally open when the toggle switch is in the maintained off position.\u003c\/p\u003e\n\u003cp style=\"padding-left: 60px;\"\u003e\u003cstrong\u003eIn00 - In05\u003c\/strong\u003e - four state simulation:\u003c\/p\u003e\n\u003cp style=\"padding-left: 90px;\"\u003eMaintained Off or Normally Open\u003c\/p\u003e\n\u003cp style=\"padding-left: 90px;\"\u003eMaintained On or Normally Closed\u003c\/p\u003e\n\u003cp style=\"padding-left: 60px;\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e2. Six highly visible illuminated indicators as output field device simulators:\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003eThe electrical interface (field wiring) to the six output field device simulation is one common conductor to all six 24vdc LED illuminated pushbuttons connected to the negative (ovdc - common) terminal of the indicators and one dedicated conductor per indicator for landing on the I\/O modules terminal block. They are polarity sensitive, negative common and positive (24vdc) from each output terminal to each indicator. Integration with relay output modules is the simplest. Make sure that your output module is compatible with this circuit type.\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003e\u003cstrong\u003eLarger\u003c\/strong\u003e and \u003cstrong\u003emulticolor\u003c\/strong\u003e indicators allow quicker determination of the state of the outputs controlled by your controller\u003c\/p\u003e\n\u003cp\u003e3. The enclosure has dual 24vdc power connectors connected in parallel to allow daisy chaining to additional field device simulations.\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003eWe include a 24vdc power adapter with this field device simulator. The power adapter has sufficient capacity to power at least two of our field device simulators.\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003eWe have not posted a photo of the power adapter because the physical form may vary, but not the capacity.\u003c\/p\u003e\n\u003cp\u003e4. The enclosure is professionally machined and digitally printed.\u003c\/p\u003e\n\u003cp\u003e5. Flyout leads are a minimum of 12 inches. Longer leads available for quote.\u003c\/p\u003e","brand":"PLC Professor","offers":[{"title":"Default Title","offer_id":12275387649,"sku":"DFDS-24-1_","price":585.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1178\/7298\/products\/Product_IMG_0330.jpg?v=1459452212"},{"product_id":"39-digital-field-device-simulator-enclosure-machined-and-printed-with-all-major-components-with-instructions","title":"39 - Digital Field Device Simulator Enclosure (Machined and Printed) with all Major Components \u0026 with Instructions","description":"\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eAllow 30 days for high quantities...\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThis product is a fully machined and printed enclosure ready to receive the provided components to build a digital field device simulator. This system simulates six digital inputs and six digital outputs. The six digital input simulations allow four states: maintained off, maintained on, momentary on and momentary off.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #2b00ff;\"\u003eIncluded with the \u003cspan style=\"text-decoration: underline;\"\u003eenclosure\u003c\/span\u003e is a complete set of instructions for mounting the components and wiring the system.\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\n\u003cspan style=\"color: #2b00ff;\"\u003e\u003c\/span\u003e\u003cspan style=\"color: #0076ff;\"\u003e\u003cspan style=\"color: #ff0000;\"\u003eThese can be ordered fully assembled\u003c\/span\u003e and tested by quote only. Contact us with the quantity and we will quote them fully assembled and tested.\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThis design is for a universal I\/O simulator with six multipurpose input simulators and six highly visible output simulators:\u003c\/p\u003e\n\u003cp\u003eThis field device simulator can be integrated with any controller, any size and any brand.\u003c\/p\u003e\n\u003cp\u003e1. Six multipurpose input field device simulators:\u003c\/p\u003e\n\u003cp\u003eMulti-state simulator; using a selector switch or a pushbutton alone can be awkward to operate when exercising your logic in the controller.\u003c\/p\u003e\n\u003cp\u003eThe electrical interface (field wiring) to the six input field device simulation is one common conductor to all six pairs of switches and one dedicated conductor per pair for landing on the I\/O modules terminal block. They are not polarity sensitive, they are all dry contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaintained ON\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMaintained Off\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- There are instances that you would like to change the state of a simulated input field device and leave it in that state indefinitely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNormally Open\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNormally Closed\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- There are other situations where a single hand motion to change the state momentarily reduces distraction from concentrating on the code and not the simulation of field devices. This is where a pushbutton is the best solution.\u003c\/p\u003e\n\u003cp\u003eIn most cases... A normally open pushbutton will suffice for the quick momentary change of state and for that reason all six of our input field device simulators have an adjacent pushbutton that functions as normally open when the toggle switch is in the maintained off position.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn00 - In05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- four state simulation:\u003c\/p\u003e\n\u003cp\u003eMaintained Off or Normally Open\u003c\/p\u003e\n\u003cp\u003eMaintained On or Normally Closed\u003c\/p\u003e\n\u003cp\u003e2. Six highly visible illuminated indicators as output field device simulators:\u003c\/p\u003e\n\u003cp\u003eThe electrical interface (field wiring) to the six output field device simulation is one common conductor to all six 24vdc LED illuminated pushbuttons connected to the negative (ovdc - common) terminal of the indicators and one dedicated conductor per indicator for landing on the I\/O modules terminal block. They are polarity sensitive, negative common and positive (24vdc) from each output terminal to each indicator. Integration with relay output modules is the simplest. Make sure that your output module is compatible with this circuit type.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLarger\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emulticolor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicators allow quicker determination of the state of the outputs controlled by your controller.\u003c\/p\u003e\n\u003cp\u003e3. The enclosure has dual 24vdc power connectors connected in parallel to allow daisy chaining to additional field device simulations.\u003c\/p\u003e\n\u003cp\u003e4. The enclosure is professionally machined and digitally printed.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e5. All of the major components are supplied with this kit. We do not supply solder, wire or tools but the instructions include information regarding where and what to purchase.\u003c\/p\u003e\n\u003cp\u003e6. Three of the openings are bored to the smallest available components, 2 bulkhead connectors and the pilot light. You may have to increase the opening to accept those parts...be very careful not to oversize the openings. I suggest that you purchase a uni-bit as shown in the instructions and increase the opening one size at a time, checking the fit of the pilot light after each increase.\u003c\/p\u003e","brand":"PLC eUniversity","offers":[{"title":"Default Title","offer_id":36001694941344,"sku":"DFDS-24","price":239.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1178\/7298\/products\/IMG_4879e.jpg?v=1598983048"},{"product_id":"copy-of-29-universal-analog-field-device-simulator-field-extendable-i-o-special-order-only","title":"KIT Only - Universal Analog Field Device Simulator - Field Extendable I\/O","description":"\u003cp\u003eThis is a kit!!!\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #fd0303;\"\u003eThis kit does not include any wire, solder or connectors, major parts only with instruction via photos emailed to your provided email address. If the email address provided with the purchase is not yours, you need to make other arrangements. \u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003eIt does include the DC bucking voltage converter but is not shown in the images.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eA universal I\/O simulator with four multipurpose input simulators and two multipurpose output simulators. \u003cstrong\u003eThis field device simulator can be integrated with any controller, any size and any brand.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor most learning activities, a potentiometer will suffice to simulate an analog input value.\u003c\/p\u003e\n\u003cp\u003e1. Four multipurpose input field device simulators:\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003eAnalog Voltage Inputs - Field Extendable\u003c\/p\u003e\n\u003cp style=\"padding-left: 60px;\"\u003eFor most learning activities, a potentiometer will suffice to simulate an analog input value.\u003c\/p\u003e\n\u003cp style=\"padding-left: 90px;\"\u003eIno (Ch0) and In3 (Ch3) provides a 0-10vdc signal to the controllers analog input module, manually variable by adjusting the potentiometers from minimum (ccw) to maximum (cw).\u003c\/p\u003e\n\u003cp style=\"padding-left: 60px;\"\u003eAlthough a potentiometer is sufficient for introductory observation of analog values influencing the execution of logic in your controller, there are many learning opportunities that cannot be realized without connecting a analog signal source that is influenced by outside forces such as temperature, pressure, etc... In addition to those learning opportunities, there are opportunities to configure and test field devices by connecting them via the field extendable features of this simulator.\u003c\/p\u003e\n\u003cp style=\"padding-left: 90px;\"\u003eIno (Ch0) and In3 (Ch3) by means of the toggle (selector) switch will accept a 0-10vdc signal from any compatible source external to the simulator, typically a transmitter or signal conditioner.\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003eAnalog Voltage\/Current Inputs - Field Extended Only, Selectable (0-10vdc or 0-20ma) by means of the toggle (selector) switch.\u003c\/p\u003e\n\u003cp style=\"padding-left: 60px;\"\u003eFor most learning activities, 0-10vdc analog input simulation is sufficient. However, 0-20ma or 4-20ma are more prevalent for actual analog field devices and this is available with this simulator by means of a toggle (selector) switch.\u003c\/p\u003e\n\u003cp style=\"padding-left: 90px;\"\u003eIn1 (Ch1) and In2 (Ch2) provides access to an external source for a 0-10vdc or 0-20ma analog signal such as a transmitter or signal conditioner.\u003c\/p\u003e\n\u003cp\u003e2. Two multipurpose output field device simulators:\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003eAnalog Voltage Outputs - Field Extendable\u003c\/p\u003e\n\u003cp style=\"padding-left: 90px;\"\u003eOut0 (Ch0) and Out1 (Ch1) provide a constant visual indication of the analog output values.\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003eAlthough a voltmeter is sufficient for introductory observation of analog values influenced by the execution of logic in your controller, there are many learning opportunities that cannot be realized without connecting a analog signal to an external device such as a VFD or PWM driver. In addition to those learning opportunities, there are opportunities to configure and test field devices by connecting them via the field extendable features of this simulator.\u003c\/p\u003e\n\u003cp style=\"padding-left: 90px;\"\u003eOut0 (Ch0) and Out1 (Ch1) are extendable to external devices without interrupting the voltmeter display. This allows a verification of signal when testing externally controlled analog devices.\u003c\/p\u003e\n\u003cp\u003e3. The enclosure has dual 24vdc power connectors connected in parallel to allow daisy chaining to additional field device simulations.\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003eWe include a 24vdc power adapter with this field device simulator. The power adapter has sufficient capacity to power at least two of our field device simulators.\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003eWe have not posted a photo of the power adapter because the physical form may vary, but not the capacity.\u003c\/p\u003e\n\u003cp\u003e4. The enclosure is professionally machined and digitally printed.\u003c\/p\u003e","brand":"PLC Professor","offers":[{"title":"Default Title","offer_id":40235786731717,"sku":"","price":289.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1178\/7298\/products\/IMG_5038ed.jpg?v=1627486711"},{"product_id":"copy-of-28-universal-digital-field-device-simulator-use-with-plc2-3-5-slc500-micrologix1000-1100-1200-1400-1500-controllogix-or-compactlogix-or-any-plc-with-dc-i-o","title":"30- Universal Digital Field Device Simulator Wired to I\/O Module Terminal Blocks","description":"\u003cp\u003e\u003cstrong\u003ePlease allow 10 to 15 business days for shipment of this product.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #0000ff;\"\u003eThese are specifically built to allow unplugging the RTBs from you existing CompactLogix controllers and plugging these in to use the Digital Field Device Simulators with existing learning\/lab stations such as Festo, Amitrol etc...Eliminating the need to modify your training stations that are already permanently connected the other input and output devices.\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003eThe images are for 1769 I\/O RTBs with 24\" extensions. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eThese are also available for any length, any controller and any manufacturer but only by quote...contact us for quote...do not order unless you want exactly what is in the images...Discounts available for large quantities.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eA universal I\/O simulator with six multipurpose input simulators and six highly visible output simulators:\u003c\/p\u003e\n\u003cp\u003eThis field device simulator can be integrated with any controller, any size and any brand.\u003c\/p\u003e\n\u003cp\u003e1. Six multipurpose input field device simulators:\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003eMulti-state simulator; using a selector switch or a pushbutton alone can be awkward to operate when exercising your logic in the controller.\u003c\/p\u003e\n\u003cp style=\"padding-left: 60px;\"\u003eThe electrical interface (field wiring) to the six input field device simulation is one common conductor to all six pairs of switches and one dedicated conductor per pair for landing on the I\/O modules terminal block. They are not polarity sensitive, they are all dry contacts.\u003c\/p\u003e\n\u003cp style=\"padding-left: 60px;\"\u003e\u003cstrong\u003eMaintained ON\u003c\/strong\u003e or \u003cstrong\u003eMaintained Off\u003c\/strong\u003e - There are instances that you would like to change the state of a simulated input field device and leave it in that state indefinitely.\u003c\/p\u003e\n\u003cp style=\"padding-left: 60px;\"\u003e\u003cstrong\u003eNormally Open\u003c\/strong\u003e or \u003cstrong\u003eNormally Closed\u003c\/strong\u003e - There are other situations where a single hand motion to change the state momentarily reduces distraction from concentrating on the code and not the simulation of field devices. This is where a pushbutton is the best solution.\u003c\/p\u003e\n\u003cp style=\"padding-left: 90px;\"\u003eIn most cases... A normally open pushbutton will suffice for the quick momentary change of state and for that reason all six of our input field device simulators have an adjacent pushbutton that functions as normally open when the toggle switch is in the maintained off position.\u003c\/p\u003e\n\u003cp style=\"padding-left: 60px;\"\u003e\u003cstrong\u003eIn00 - In05\u003c\/strong\u003e - four state simulation:\u003c\/p\u003e\n\u003cp style=\"padding-left: 90px;\"\u003eMaintained Off or Normally Open\u003c\/p\u003e\n\u003cp style=\"padding-left: 90px;\"\u003eMaintained On or Normally Closed\u003c\/p\u003e\n\u003cp style=\"padding-left: 90px;\"\u003e \u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003e2. Six highly visible illuminated indicators as output field device simulators:\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003eThe electrical interface (field wiring) to the six-output field device simulation is one common conductor to all six 24vdc LED illuminated pushbuttons connected to the negative (ovdc - common) terminal of the indicators and one dedicated conductor per indicator for landing on the I\/O modules terminal block. They are polarity sensitive, negative common and positive (24vdc) from each output terminal to each indicator. Integration with relay output modules is the simplest. Make sure that your output module is compatible with this circuit type.\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003e\u003cstrong\u003eLarger\u003c\/strong\u003e and \u003cstrong\u003emulticolor\u003c\/strong\u003e indicators allow quicker determination of the state of the outputs controlled by your controller.\u003c\/p\u003e\n\u003cp\u003e3. The enclosure has dual 24vdc power connectors connected in parallel to allow daisy chaining to additional field device simulations.\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003eWe include a 24vdc power adapter with this field device simulator. The power adapter has sufficient capacity to power at least two of our field device simulators.\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003eWe have not posted a photo of the power adapter because the physical form may vary, but not the capacity.\u003c\/p\u003e\n\u003cp\u003e4. The enclosure is professionally machined and digitally printed.\u003c\/p\u003e\n\u003cp\u003e5. These are shown with a typical length of cable between the simulator and the I\/O modules. The price shown is typical and only for the configuration shown.\u003c\/p\u003e\n\u003cp\u003e6. Terminal blocks allow the maximum flexibility with your training or lab equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. Includes 24vdc power adapter.\u003c\/strong\u003e\u003c\/p\u003e","brand":"PLC Professor","offers":[{"title":"Default Title","offer_id":42216249721029,"sku":"","price":1259.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1178\/7298\/files\/dfdswired06.jpg?v=1686163165"}],"url":"https:\/\/shop.plcprofessor.com\/collections\/hardware-for-the-complete-paclearn-series.oembed","provider":"PLC eUniversity","version":"1.0","type":"link"}